INSTALLATION
INSTRUCTIONS
Your pump has been carefully packaged at the
factory to prevent damage during shipping.
However, occasional damage may occur due to
rough handling. Carefully inspect your pump
for damages that could cause failures. Report
any damage to your carrier or your point
of purchase.
© 2013 BUR-CAM Printed in Canada 400391
MODEL
400500
400510
400500E
SEWAGE
PUMPS
INITIAL START UP PROCEDURES:
1.
Inspect the pump and the sewage tank for
any obvious condition that may
necessitates cleaning, correction,
adjustement or repair.
2. Assure that the pump is secure and
vertical for proper operation.
3. Assure that there is adequate clearance
from any combustible materials or
structure. Stored materials must be kept
away from the pump. Shelves or cabinet
structures must not be in close proximity
over the pump.
4. Assure that the motor is securely plugged
into a proper ‘GFCI’ electrical outlet.
5. Test the ‘GFCI’ outlet by pressing its test
switch. This should prove that the outlet is
energized and will trip off to protect against
a ground fault. Be sure to reset the ‘GFCI’
by pressing its reset switch.
(Repeat this step monthly)
6.
Lift the float to assure that the pump will
start when required. (Step 7 below will
test submersible pumps with enclosed
floats).
7. Pour pails of water in the sewage tank to
turn the pump on. Assure that any check
valve present will permit the sewage to flow.
8. Observe that the plumbing can pump the
sewage safely out of the residence.
(Repeat this step monthly)
www.burcam.com
2190 Dagenais Blvd. West TEL: 514.337.4415
LAVAL (QUEBEC) FAX: 514.337.4029
CANADA
Please read these
instructions carefully.
Failure to comply to
instructions and
designed
operation of this
system, may
void the
warranty.
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - INSTRUCTIONS

INSTALLATIONINSTRUCTIONSYour pump has been carefully packaged at thefactory to prevent damage during shipping.However, occasional damage may occur due

Page 2 - SAFETY INSTRUCTIONS:

SAFETY INSTRUCTIONS:Before installation and operation, follow these procedures:Check with your local electrical and plumbing codes to ensure you compl

Page 3 - IMPORTANTE NOTICE

3APPLICATIONSDesigned for a permanent installation for homes and cottages application. To pumping where the total head requirements do not exceed 15

Page 4 - SEWAGE SYSTEM TYPICAL PIPING

Screw the pipe with the male adaptor into the 2” discharge opening in the pump. Lowerpump with piping attached into the sewage basin. Make sure that t

Page 5 - SEWAGE PUMP APPLICATION

REPAIR PARTSSTEP 3Cement 2” adaptor topipeSTEP 2Install sewage basinSTEP 4Drill a 1/4” holeSEWAGE PUMP APPLICATIONSTEP 5Install dischargepipe and lowe

Page 6

6TROUBLE SHOOTING GUIDE CHECKLISTNEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THEPOWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR